Plant room  ·  compact  ·  complete  ·  connected
Request information

The plant room
In a single module

Compact Complete Connected
Presentation of the HYDROCLOUD module

Installable in two hours,
remotely monitorable.

MADE IN EUROPE 6-YEAR CYLINDER WARRANTY 0.6 m² FOOTPRINT
65 L
Buffer tank
210 L
DHW storage
13 kW
Compatible heat pumps
0.6 m²
Floor space
246 kg
Empty weight

Everything you need
Already in place

Explore the module

One single plant room

Less floor space

Everything in about 0.6 m².
The space taken up by a traditional plant roomThe same space with only the HYDROCLOUD module: about 0.6 m²

Factory pre-wired

Less work
On site

Power supplies and interlocks already gathered.
Pre-wired terminal block and electrical connections inside the HYDROCLOUD module

+ Cloud monitoring

Your system
Always in view

Monitoring, history and notifications.
HYDROCLOUD monitoring dashboard on computer and smartphone

Fewer constraints on site
Faster installation

The everyday limits
01
Time — When?
When you spend too much time on site assembling components.
02
Space — Is there any?
When plant rooms keep getting tighter and more complex.
03
Labor — Where is it?
When experienced installers are hard to find and coordinate.
✓
Fast installation
Less work on site
✓
Compact footprint
Integrated and accessible
✓
Pre-wired solution
Electrical terminal block ready
✓
Single point of contact
Fewer orders, more free time
2 hoursaverage
installation time
See it with Eng. Trento

The module, live

Internal components, maintenance access and the on-site connection sequence.

Hydraulic diagram

What's inside
Versatility in0.6 m²

Circuit 1 · directCircuit 2 · mixedBuffer tank 65 lExpansion vesselDHWStorage 210 lSolar thermalCWSExpansion vesselY-filterMagnetic dirt separatorHeat pump outdoor unitup to 13 kWHEATINGCOOLINGDOMESTIC HOT WATER

Connections and fittings

Eight 1" connections
on top

Cable glands for the electrical side
Rear view of the HYDROCLOUD module with the eight 1" connections on top and the electrical cable glands
Fittings and pipe routing

Steel
fittings

Angled top for pipe routing

Detail of the stainless-steel hydraulic fittings on the module's angled top
Pre-wired HYDROCLOUD terminal block with switches, contactor, terminals and DIN rail
Electrical connections

Pre-wired
terminal block

  • Power supplies and interlocks

    The main power supplies and interlocks are already gathered in the module's terminal block.

  • 3-way valve

    The 3-way valve's electrical connection is already pre-wired.

  • Secondary circulator

    The secondary circulator is already pre-wired in the terminal block.

  • Electric heating element

    The flow electric heating element is already pre-wired.

  • Temperature sensors

    Conduits are provided for the heat pump's temperature sensors.

  • Expansions on DIN rail

    A free section of DIN rail is available for expansions.

Available configurations

Choose your configuration

Configure your request.

System zones
Solar-thermal readiness
Cloud monitoring
ZonesBaseSolar+ Monitoring
1 zoneHY1HY1S+ CLOUD
2 zoneHY2HY2S
Cloud monitoring video

See what's happening
remotely, from an app, anywhere

Monitoring is independent: it observes the system through dedicated temperature sensors, a current clamp and a dry contact. It doesn't communicate with the heat pump and doesn't change how it operates.
✓Key parameters

See the system's status at a glance: temperatures, current draw, instantaneous power.

✓History and trends

A black box for the system, so you can understand what happened, even weeks later.

✓Alerts

Custom notifications for anomalies, for predictive maintenance and fewer unnecessary site visits.

Technical data

Everything integrated
Everything accessible
All in one

Also available with solar-thermal integration. Components are accessible from the front for maintenance thanks to removable panels.

In short: about 0.6 m² of floor space, 246–257 kg, 210 l domestic hot water storage with a 6-year warranty, compatible with air-to-water heat pumps up to 13 kW, installation in about two hours.

Inside the HYDROCLOUD module: brass hydraulic groups, dirt separator and insulated pipework
[ interior · hydraulic side ]
Buffer tank (hydraulic separator)65 l
Domestic hot water storage210 l · 6-year warranty
Heat pump compatibilityair-to-water up to 13 kW
System zones1 direct · 2nd mixed (HY2)
Floor space≈ 0.6 m² (743 mm wide)
Height including fittings1953 mm
Empty weight246 / 257 kg
Hydraulic connections1" female threaded
Electrical panelpre-wired terminal block
+ free DIN rail
Insulation50 mm polyurethane foam
Outer claddingremovable · RAL 9016
Monitoringoptional
Solar thermalHY1S / HY2S

Frequently asked questions

Contact

Request
information

We reply within one business day with the reserved price list, technical data sheets and availability. No obligation.

✓Reply within one business day
✓Price list reserved for installers and designers
✓Technical support during sizing
* required fields · data processed under EU Reg. 2016/679